美國(guó)ATCC>
ATCC菌種類(lèi)>
金黃色葡萄球菌金葡亞種Staphylococcus aureus subsp. aureus Rosenbach 拉丁名
(ATCC® 29213™) 統(tǒng)一編號(hào)
Strain Designations 菌種別名 Wichita
Application 用途 Quality control strain
Susceptibility disc testing
Susceptibility testing
Quality control strain for API, BBL, bioMerieux Vitek, Micro-Media, MicroScan®, and Sensititre products
Drug discovery
Enteric Research
Isolation Wound
Biosafety Level 生物安全等級(jí)2
Product Format 提供形式 freeze-dried
Storage Conditions 保藏方法
Frozen(冷凍物): -80℃ or colder
Freeze-Dried(凍干物): 2℃ to 8℃
Live Culture: See Propagation Section
Preceptrol® yes
Type Strain 模式菌株 no
Antibiotic Resistance Sensitive to oxacillin
Comments 注釋 Sensitive to oxacillin
Medium 培養(yǎng)基 ATCC® Medium 18: Trypticase Soy Agar/Broth
Growth Conditions 生長(zhǎng)條件
Temperature 培養(yǎng)溫度: 37℃
Atmosphere 需氧情況: Aerobic
Name of Depositor 寄存人 Micro-Media Systems, Inc.
Chain of Custody 來(lái)源國(guó)家 ATCC <-- Micro-Media Systems, Inc. <-- EH Gerlach strain Wichita
Isolation 分離源 Wound
References 參考文獻(xiàn) Performance Standards for Antimicrobial Disk Susceptibility Tests; Approved Standard - 9th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M2-A9.
Methods for Dilution Antimicrobial Susceptibility Tests for Bacteria that Grow Aerobically; Approved Standard - 7th Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M7-A8.
Performance Standards for Antimicrobial Disk and Dilution Susceptibility Tests for Bacteria Isolated from Animals; Approved Standard - 2nd Edition. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M31-A3.
Performance Standards for Antimicrobial Susceptibility Testing; Sixteenth Informational Supplement. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M100-S20, 2007
API ID 32 STAPH. bioMerieux.
BD Phoenix Gram Positive AST PMIC/ID QC Set. BD Becton Dickinson; Phoenix
MicroScan Dried Gram Positive Panel QC Set. Dade/Siemens.
MicroScan Dried Gram Negative Panel QC Set. Dade/Siemens.
Sensititre™ MIC Susceptibility. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems.
Sensititre™ Mycobacterium Susceptibility. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems.
Susceptibility Testing of Mycobacteria, Nocardiae, and Other Aerobic Actinomycetes; Approved Standard. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M24-A.
Susceptibility Testing of Mycobacteria, Nocardiae, and Other Aerobic Actinomycetes; Table 9 Supplement. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M24-S1.
Evaluation of Lots of Dehydrated Mueller-Hinton Broth for Antimicrobial Susceptibility testing; Proposed Guideline. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M32-P.
Methods for Antimicrobial Dilution and Disk susceptibility Testing of Infrequently Isolated or Fastidious Bacteria: Proposed Guideline. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M45-A.
Methods for Broth Dilution Susceptibility Testing of Bacteria Isolated from Aquatic Animals. Wayne, PA. Clinical and Laboratory Standards Institute; CLSI M49-A.
Medical microbiology; methods for the determination of susceptibility of pathogens (except mycobacteria) to antimicrobial agents: agar diffusion test. Berlin, Germany: Deutsches Institut fur Normung; DIN 58940-3: 1989
Medical microbiology -- Methods for the determination of susceptibility of pathogens (except mycobacteria) to antimicrobial agents-- Part 7: Determination of the minimum bactericidal concentration (MBC) with the aid of microdilution. Berlin, Germany:Deutsches Institut fur Normung;DIN DIN 58940-7: 1994, 1994
Medical microbiology: methods for the determination of susceptibility of pathogens (except mycobacteria) to antimicrobial agents; determination of MICs by agar dilution method. Berlin, Germany:Deutsches Institut fur Normung;DIN DIN 58940-6: 1989, 1989
Medical microbiology -- Susceptibility testing of microbial pathogens to antimicrobial agents -- Part 81: Microdilution; Special requirements for testing of non-fastidious bacteria. Berlin, Germany: Deutsches Institut fur Normung; DIN 58940-81: 2002
Clinical laboratory testing and in vitro diagnostic test systems --- Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices --- Part 1: Reference method for testing the in vitro activity of antimicrobial agents against rapidly growing aerobic bacteria involved in infectious diseases. London, UK:British Standards Institution;British Standard BS EN ISO 20776-1:2006.
VITEK 2 AST-GP QC Set. bioMerieux.
MicroScan Synergies plus Gram Positive QC Set. Dade/Siemens.
ISO/CD 11133:2009, Annex E. Test microorganisms for commonly used culture media (giving information on the culture medium, culture conditions, test microorganisms, culture collection number of test organisms and the expected reactions)
Corry, JEL, Curtis, GDW and Baird, RM (Eds) Handbook of Culture Media for Food and Water Microbiology. Royal Society of Chemistry, In preparation. ICFMH-WPCM.
Sensititre™ MIC Breakpoint QC Set/5. Thermo Scientific™ Sensititre™ Systems, Trek Diagnostic Systems.
BD MAX™ StaphSR Assay. BD Becton Dickinson.
Cross References
Nucleotide (GenBank) : U77328 Staphylococcus aureus staphylokinase gene, partial cds.
固定電話(huà):010-53515223
業(yè)務(wù)手機(jī):18610886853,18610241664,18701099593,18971386853,18701098095
微信號(hào)碼:vrmte521(18610886853企業(yè)微信);18610241664;biobw0905(18701098095)
企業(yè)公眾號(hào):800185668
官方郵箱:biobw11@sina.com(微生物菌種查詢(xún)網(wǎng))
投訴電話(huà):biobw8888(18701099593)